PioNext Ultra Quick Start Guide

Oct 16, 2026
  • Please refer to this guide to complete the installation and printing of the printer.
  • Safety Notice: Do not power on the printer before installation is complete.
  • Please visit the PioCreat website for more products operation and maintenance tutorials. Open the supplied USB drive to view the video tutorials. The UI interface is only for reference, and shall be subject to the actual UI.

Component Introduction

Component Introduction
Component Introduction

Included Accessories

Item

Qty

Item

Qty

Build platform

1

Plastic blade

1

Resin vat

1

Metal blade

1

Resin vat dust cover

1

Cutting pliers

1

Power cable

1

Paintbrush

1

Calibration card

1

USB A to A cable

1

USB drive

1

Quality certificate

1

Hex key set H2.0 H2.5 H3.0 H4.0

1 set

Quick start guide

1

Disposable latex gloves

1

After sales service card

1

Filters

4

 

 

Quick Start Operation Schematic

1. Unpack the accessories such as the dust cover of the resin tank and the power cable, remove the protective foam from the top and the right side of the machine.

Remove the top protective foam
Remove the top protective foam

2. Remove the seamless tape between the hood and the base, open the hood, and take out all the foam inside the machine.

Remove the tape between the hood and the base
Remove the tape between the hood and the base

3. Once the power cord is connected, turn on the device switch to complete the startup operation.

Connect power and switch on the device
Connect power and switch on the device

First Printing

1. A. Fill the resin vat. B. Insert the included USB drive.

Fill the resin vat and insert the USB drive
Fill the resin vat and insert the USB drive

2. Tap Print on the home page.
3. Select the pre-sliced file stored in the device.
4. Click Start to start the first print.

First printing steps 2 to 4
First printing steps 2 to 4

Connect AFU Optional

1. A. Plug one end of the AFU control cable into the I/O port. B. Thread the feed hose through the AFU material pipe through-hole.

Connect the AFU control cable and feed hose
Connect the AFU control cable and feed hose

2. Remove the laser module and install it into the fixed position on the resin tank. Press down until the buckle makes a click sound.

Install the laser module on the resin vat
Install the laser module on the resin vat

3. A. Insert the control cable vertically into the connection port of the laser module. B. Insert the feed hose vertically into the feed port of the laser module.

Insert the control cable and feed hose
Insert the control cable and feed hose

4. Click Settings > Feeding System on the main interface. If you can successfully access the Feeding System, it indicates that the AFU has been connected.

Open Feeding System after connecting the AFU
Open Feeding System after connecting the AFU

Connect Device to Network and Install Software

In the main interface of the device, go to Settings > System Settings > WLAN, select the Wi-Fi you want to connect to, and network the device.

Connect the device to WLAN
Connect the device to WLAN

Download the installation package from www.piocreat3d.com. Or install from included USB drive.

PioNext BOX and CHITUBOX Dental
PioNext BOX and CHITUBOX Dental

Tips: This product supports CHITUBOX Dental. Contact customer service to receive a free 3-month CHITUBOX Dental slicing software license.

Technical Specifications

Parameter

Specification

Build volume

211.68 × 118.37 × 100 mm

Printer dimensions

468 × 286 × 470 mm

Package dimensions

600 × 370 × 585 mm

Net weight

19.78 kg

Gross weight

23.67 kg

Printing technology

LCD

Light source wavelengths

385 nm and 405 nm

Resolution

16K 15120 × 6230 px

Pixel size

14 × 19 μm

Layer thickness

0.01–0.1 mm

Printing speed

Up to 60 mm/h at 0.1 mm layer thickness

Touchscreen

5 inch capacitive color touchscreen

Slicing software

PioNext BOX and CHITUBOX Dental

File transfer

USB drive and WLAN

Input voltage

100–240 V AC 50/60 Hz

Rated power

660 W

Supported materials include Removable Die Model, Ortho Model, Ortho Model 2.0, Dental Casting, Surgical Guide, Surgical Guide Pro, Temporary Restoration, Denture Base and Crown & Bridge resins and other officially authorized resins.

Regulatory Information

Canada ISED

The device contains license exempt transmitters and receivers that comply with Innovation, Science and Economic Development Canada RSS requirements. It must not cause interference and must accept interference, including interference that may cause undesired operation.
The device meets the routine evaluation exemption in section 6 of RSS 102 and the applicable RF exposure requirements. Canadian RF exposure and compliance information is available to users. Maintain at least 20 cm between the radiator and your body. Do not place or operate the transmitter together with another antenna or transmitter. This product is designed for indoor use only.

United States FCC

The device complies with FCC Part 15. It must not cause harmful interference and must accept received interference, including interference that may cause undesired operation. Changes or modifications that are not expressly approved by the responsible compliance party may void the user's authority to operate the equipment.
The equipment has been tested against the Class B digital device limits under FCC Part 15, intended to provide reasonable protection in residential installations. It generates, uses and can radiate radio frequency energy. Incorrect installation or use can interfere with radio communications; interference may still occur in a particular installation.
If switching the equipment off and on confirms interference with radio or television reception, try these measures:

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the equipment and receiver.
  • Connect the equipment to an outlet on a different circuit from the receiver.
  • Consult the dealer or an experienced radio or television technician.

The equipment meets FCC radiation exposure limits for an uncontrolled environment. Maintain at least 20 cm between the radiator and your body, and do not operate the transmitter together with another antenna or transmitter.